• The Local Display 0.5% Accuracy Pd Mechanical Oval Gear Flow Meter
  • The Local Display 0.5% Accuracy Pd Mechanical Oval Gear Flow Meter
  • The Local Display 0.5% Accuracy Pd Mechanical Oval Gear Flow Meter
  • The Local Display 0.5% Accuracy Pd Mechanical Oval Gear Flow Meter
  • The Local Display 0.5% Accuracy Pd Mechanical Oval Gear Flow Meter
  • The Local Display 0.5% Accuracy Pd Mechanical Oval Gear Flow Meter

The Local Display 0.5% Accuracy Pd Mechanical Oval Gear Flow Meter

Accuracy: ±0.2-0.5%
Main Application: Diesel Fuel, Fuel Oil, Various Oil
Size: Dn10-150
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
The Local Display 0.5% Accuracy Pd Mechanical Oval Gear Flow Meter pictures & photos
The Local Display 0.5% Accuracy Pd Mechanical Oval Gear Flow Meter
US $122 / Piece
Min. Order: 1 Piece
Diamond Member Since 2009

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
Oval Gear Flow Meter
Type
Ovak
Measuring Media
Liquid
Measuring Principle
Positive Displacement
Certification
CE, ISO, SGS
Volume
42×42×40 Cm
Installation
Easy
Exported
More 80 Countries
Quality
World-Class
Maintenance
Less and Easy
Transport Package
Wooden Cases
Specification
CE, SGS, ISO
Trademark
GN
Origin
Shanghai, China
Production Capacity
5000 PCS/Month

Product Description

The Local Display 0.5% Accuracy Pd Mechanical Oval Gear Flow Meter
The Local Display 0.5% Accuracy PD Mechanical Oval Gear Flow Meter

A.[Features of Oval Gear Flow Meter]

1-Widely range of liquid viscosity

the viscosity of medium is 0.6Mpa.s~250Mpa.s 

2-Various of Display and Output

The Cast iron material PD Mechanical Oval Gear Flow Meter with digital display and mechanical display ;pulse or 4~20mA Output;

3-Various applications 

the Cast iron material PD Mechanical Oval Gear Flow Meter suitabke for various applications such as chemical industry ,oil,medicine and electricity,etc.

4-High accuracy

Beacuse of the principle of Cast iron material PD Mechanical Oval Gear Flow Meter,the accuracy is 0.5% or 0.2%.

B.[Parameters]

 Production Name  Cast iron material PD Mechanical Oval Gear Flow Meter
 Medium  Main Medium is Oil
 Accuracy  0.5% or 0.2%
 Output  Pulse output ,4~20mA Output and without output
 Material  Cast iron,cast steel or stainless steel material
 Display  LCD Display or Local Mechanical display
 Function  Return to zero function
 Accessories  ''Y''Filter or square filter
 Temperature  -20~100ºC
 Viscosity  0.6Mpa.s~250Mpa.s

 

Model

Connection

Flow rate(L/H)

0.6~2map.s

2~8map.s

8~200map.s

DT-O-10

1/2"~3/8"

40~400

40~400

40~400

DT-O-15

Flange 4*Φ14

380~1500

200~1500

150~1500

DT-O-20

Flange 4*Φ14

750~3000

400~3000

300~3000

DT-O-25

Flange 4*Φ14

1500~6000

800~6000

600~6000

DT-O-40

Flange 4*Φ18

3000~15000

2000~15000

1500~15000

DT-O-50

Flange 4*Φ18

4800~24000

3200~24000

2400~24000

DT-O-80

Flange 4*Φ18

12000~60000

8000~60000

6000~60000

DT-O-100

Flange 4*Φ18

20000~100000

13000~100000

10000~100000

DT-O-150

Flange 4*Φ18

24000~120000

15000~120000

12000~120000


The Local Display 0.5% Accuracy Pd Mechanical Oval Gear Flow Meter
The Local Display 0.5% Accuracy Pd Mechanical Oval Gear Flow Meter

C.[Installation]

  • The flow direction should be same as the sign on the body,the location must be convenient for you reading.
  • The Cast iron material PD Mechanical Oval Gear Flow Meter should be installed at normal temperature location where without harmful gas to avoid damaging the flow meter;
  • Pls installa the bear horizontal state
The Local Display 0.5% Accuracy Pd Mechanical Oval Gear Flow Meter
  • Pls keep the pipeline is clear before installa the flow meter and installa the filter to avoid the Impurities got into pipe.
  • The flow adjusted value should be installed at downsteam,First,you should open the adjusted value and second to open the shut-off value.
  • Pls ensure the liquid without any gas;
  • If the mediun's viscosity is high,sometime ,you should heating to reduce the viscosity;

D[Company info]

  • Our Company is Top 10 Manufacture on Alibaba;
  • We have about 30 years of experience in Manufacture;
  • Our products have been exported to more 100 coutries and area;
  • ISO,SGS,CE and more ceterficates for you reference;
  • Patent technology and more than 3 years working life
The Local Display 0.5% Accuracy Pd Mechanical Oval Gear Flow Meter

 

 

Send your message to this supplier

*From:
*To:
avatar Ms. Agnes Peng
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
The Local Display 0.5% Accuracy Pd Mechanical Oval Gear Flow Meter pictures & photos
The Local Display 0.5% Accuracy Pd Mechanical Oval Gear Flow Meter
US $122 / Piece
Min. Order: 1 Piece
Diamond Member Since 2009

Suppliers with verified business licenses

Trading Company
Number of Employees
16
Management System Certification
ISO9001:2015