Brief introduction
The leading meters for precision flow measurement.
Low pressure drop
The meters offer direct mass flow, volume flow, density, and temperature measurement of liquids and slurries
Every meter is available with stainless steel wetted parts and a wide variety of process connections to meet your every need.
Mass flow accuracy |
±[0.2% +(zero stability /flow rate×100%) |
Mass flow repeatability |
±(1/2) ×[0.2% +(zero stability /flow rate×100%) |
Density range |
0.2 g/cm3~3.5g/cm3 |
Density accuracy |
±0.002g/cm3 |
Temperature range |
-60C-+200C |
Temperature accuracy |
±1C |
Output of current loop |
4mA~20mA |
Output of frequency/pulse |
0Hz~10kHz |
Contactor capacity of a Batch Control relay |
24V/0.1A |
Explosion-proof |
Essential safety:Exib[ib]IIBT4
Composite:Exdib[ib]IIBT4 |
Contactor form |
normal open |
Environmental Specifications |
Temperature range of fluid |
-40C-+200C |
Environmental temperature range |
0C-+40C |
Environmental humidity |
≤90% RH, non condensation |
Atmospheric pressure range |
86kPa~106kPa |
Power supply of transmitters |
Essential safety Voltage: AC(220±10%)V,(50±5%)Hz
Composite Voltage: DC (24±10%) V |
Specs |
Line Size |
Range |
Calibration Range |
Max. Pressure |
Zero Stability |
Velocity |
(mm) |
(t/h) |
(t/h) |
(MPa) |
(t/hr) |
(h m/t s) |
DN1 |
1 |
0~0.04 |
0.004~0.04 |
30.0 |
0.000008 |
353.7 |
DN3 |
3 |
0~0.35 |
0.035~0.35 |
30.0 |
0.000067 |
39.3 |
DN6 |
6 |
0~0.7 |
0.07~0.7 |
30.0 |
0.00016 |
19.65 |
DN10 |
10 |
0~1.2 |
0.12~1.2 |
30.0 |
0.0002 |
4.912 |
DN15 |
15 |
0~6.4 |
0.64~6.4 |
4.0 |
0.0011 |
2.183 |
DN25 |
25 |
0~16 |
1.6~16 |
4.0 |
0.002 |
0.902 |
DN40 |
40 |
0~40 |
4~40 |
4.0 |
0.003 |
0.334 |
DN50 |
50 |
0~65 |
6.5~65 |
4.0 |
0.006 |
0.197 |
DN80 |
80 |
0~160 |
16~160 |
2.5 |
0.01 |
0.0873 |
DN100 |
100 |
0~250 |
25~250 |
2.5 |
0.015 |
0.0544 |
DN150 |
150 |
0~550 |
55~550 |
2.5 |
0.03 |
0.0239 |