Insertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water Meter

Product Details
Customization: Available
After-sales Service: Online Instruction
Warranty: 1years
Still deciding? Get samples of US$ 299/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
16
Management System Certification
ISO9001:2015
  • Insertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water Meter
  • Insertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water Meter
  • Insertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water Meter
  • Insertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water Meter
  • Insertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water Meter
  • Insertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water Meter
Find Similar Products
  • Overview
  • Product Description
  • Product Show
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
CX-EMFM
Accuracy
±0.2-0.5%
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Size
DN10-50
Sensor
Tube/Flange
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Product Name
Electromagnetic Flow Meter
Material
Stainless Steel
Caliber
DN10-DN2000
Medium
Water
Flow Range
0.03-100000m3/H
Connection
Flange or Screw
Power Supply
AC86-220vor DC24V
Working Temperature
-20-120ºC
Transport Package
Carton
Specification
On demand supply
Trademark
GN
Origin
China
HS Code
9026100000
Production Capacity
5000PCS/Month

Product Description

Product Description

This Technology of magnetic Electromagnetic Flowmeter has a number of advantages when it comes to liquid flow measurement. The sensors are generally inserted in line into the pipes' diameter, and are therefore designed such that they do not disturb or restrict the flow of the medium under measurement. As the sensors are not directly immersed in the liquid-there are no moving parts-there are no wear and tear concerns.

The method of magnetic electromagnetic flowmeter measures the volume flow, which means the measurement is insensitive to changes in effects such as fluid density, temperature, pressure, and viscosity. Once the electromagnetic water flow sensor measurement transmitter meters is calibrated with water, it can be used to measure the other types of conductive fluid-with no additional correction. This is a significant advantage that other types of flow meters don't have.

what's the technical parameters of magnetic electromagnetic flowmeter?

Production Name  magnetic electromagnetic flowmeter
 Medium  water;wastewater;Mud and varioue kinds of conductivity liquid
 Diameter  DN10~DN2000mm
 Accuracy  +/-0.5%
 Temperature  <80ºC(rubber); <180ºC(PTFE)
Pressure  4.0Mpa(DN10~80);1.6Mpa(DN100~150);1.0Mpa(DN200~1000);0.6Mpa(DN1200~2000)
 Flow speed  0.3~10m/s
 Requirement of   pipeline  Upstream ≥5DN;Downstream≤3DN
 Electrode  Stainless steel 316L(standard);Titanium;Tantalum;Hastelloy
 Lining  PTFE;Rubber
 Connection  Flange;thrad;clamp on
 Body material  Cast steel ;stainless steel 
 Power supply  220V;24V;Battery
 Output  Pulse;4~20mA;HART;RS485;MODBUS;GPRS
 Communication  HART;RS485;MODBUS
 Explosion proof  Customized 
 Protection  IP65 or IP68
 Environment  Environment:-20~60ºC
 Power  <20W
Product Show
Insertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water MeterInsertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water MeterInsertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water MeterInsertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water MeterInsertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water MeterInsertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water MeterInsertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water MeterInsertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water Meter

[Installation]

 1.Installation location

  • Avoid the magnetic objects and equipment with stong electromagnetoc field;
  • should installa the flow meter at ventilated location;
  • Avoid the location wherer ambient temperature above 50ºC and relative humidity above 90%;
  • The water flowmeter should be installaed at somewhere spacious;
  • The DH1000 series Digital Electromagnetic Water Flow Meter with RS485 Signal should be installaed behind pump and the value should installa at downstream.            

    2.Installa the flow sensor

  • Must to ensure the pipeline is fulled and without bubbles to keep the high accuracy;
  • The flow direction shoudl keep with sign on the body of flowmeter;
  • Ensure the double electrodes keep Horizontal;
  • If the medium is mixed by liquid and solid,Pls installa it at vertical to extend the working life of lining;
  • If the environment with shocked pls installa the bracket at both front and behind;
  • If the medium is pollution liquid,should installa the flow meter at bypass pipe and don't interrupted when you on service;

   3.Requirement of Straight pipe

  • The straight of pipe at inlet must more than 10×DN,Suggest 15DN;at outlet,the straight pipe at least 5×DN;
  • If at the upstearm of flowmeter,there are values,elbow,the straight must need 15×DN;
  • Pls installa the shut-off value at both front and behind of flow meter; 

  4.Installation advance

  • The installation location for you reference 
Company Profile

Insertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water MeterInsertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water MeterInsertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water MeterInsertion Type Electromagnetic Flow Meter Sewage Water Flowmeter with Water Meter

FAQ

 Q1. Sample Policy 
 A: Sample available if we have products in stock, but the customers have to pay the sample cost and the courier cost. We can reduce sample cost from further order according to your quantity.

 Q2. Terms of Packing 
 A: We can pack as you want,like color box,5-layer brown box.

 Q3. Terms of Payment 
 A: T/T (50% as deposit, and 50% before shipping),
Made In China Trade assurance (same safe as Paypal).Pictures of the products and packages will be showed to you before shipping. 

 Q4. Terms of Delivery 
 A: EXW, FOB, CFR, CIF, DDP, DDU.

 Q5. Delivery time 
 A: Generally, it will take 30 to 50 days after receiving payment. The specific delivery time depends on the items and the quantity of your order.

 Q6. OEM&ODM Service 
 A: ODM&OEM service accepted, including selections on size, materials, design, packing method, etc., according to your requirements. Logo and brand customization also are available. 
 
 Q7. Quality under Control 
 A: We have 100% test before delivery.Ou

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier