• Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter
  • Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter
  • Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter
  • Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter
  • Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter
  • Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter

Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter

After-sales Service: Online After-Sales Service
Warranty: 1year
Accuracy: ±0.2-0.5%
Samples:
US$ 360/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter pictures & photos
Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter
US $342-360 / Piece
Min. Order: 1 Piece
Diamond Member Since 2009

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
CX-EMFM
Main Application
Water, Wastewater, Corrosive Liquid/Gas
Size
DN50-100
Sensor
Tube/Flange
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO, SGS
Medium
Liquid
Flow Range
0.16-25000 M³/H
Connection
Flange
Output
Pulse/4-20mA/RS485
Lining Material
PTFE/Rubber
Electrode Material
SS316
Body Material
Carbon Steel/SS304
Power Supply
220V/24V/Lithium Battery
Pressure
10bar
Type and IP Code
Integrated Type IP65, Remote Type IP68
Transport Package
Carton
Trademark
GN
Origin
China
HS Code
9026100000
Production Capacity
5000PCS/Month

Product Description





Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter

 Electromagnetic Flowmeter (CX-HEMFM)

This technology of magnetic electromagnetic flowmeter has a number of advantages when it comes to liquid flow measurement. The sensors are generally inserted in line into the pipes' diameter, and are therefore designed such that they do not disturb or restrict the flow of the medium under measurement. As the sensors are not directly immersed in the liquid-there are no moving parts-there are no wear and tear concerns. 

The method of magnetic electromagnetic flowmeter measures the volume flow, which means the measurement is insensitive to changes in effects such as fluid density, temperature, pressure, and viscosity. Once the electromagnetic water flow sensor measurement transmitter meters is calibrated with water, it can be used to measure the other types of conductive fluid-with no additional correction. This is a significant advantage that other types of flow meters don't have. 

What's the technical parameters of magnetic electromagnetic flowmeter? 

Production Name Magnetic electromagnetic flowmeter
Medium Water; Wastewater; Mud and varioue kinds of conductivity liquid
Diameter DN10~DN2000mm
Accuracy +/-0.5%
Temperature <80ºC(rubber); <180ºC(PTFE)
Pressure 4.0MPa(DN10~80); 1.6MPa(DN100~150); 1.0MPa(DN200~1000); 0.6MPa(DN1200~2000)
Flow speed 0.3~10m/s
Requirement of pipeline Upstream ≥5DN; Downstream≤3DN
Electrode Stainless steel 316L(standard); Titanium; Tantalum; Hastelloy
Lining PTFE; Rubber
Connection Flange; Thrad; Clamp on
Body material Cast steel; Stainless steel
Power supply 220V; 24V; Battery
Output Pulse; 4~20mA; HART; RS485; MODBUS; GPRS
Communication HART; RS485; MODBUS
Explosion proof Customized
Protection IP65 or IP68
Environment Environment: -20~60ºC
Power <20W





Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter

Item The Electrode table
Material The Medium
SS316L For: Living water; Wastewater; Corrovise water and Mud, etc; 
Hastelloy B For: Non-oxidizing acids at concentrations less than 10%; NAOH Concentrations less than 50%
Hastelloy C For: Mixed Acid and Oxidizing salts
Titanium For: Salt and weak acid; Not application: Hydrochloric acid, nitric acid and other reducing acids
Tantalum For: Hydrochloric acid(<40%); Sulfuric acid and Other oxidizing acids
Plantinum For: Almost all acid-base salt solution But not application for aqua regia, except ammonium salt
Tungsten carbide For: Pulp; Sewage; Slurry





Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter
Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter

[Installation]

1. Installation location

  • Avoid the magnetic objects and equipment with stong electromagnetoc field; 
  • Should installa the flow meter at ventilated location; 
  • Avoid the location wherer ambient temperature above 50ºC and relative humidity above 90%; 
  • The water flowmeter should be installaed at somewhere spacious; 
  • The DH1000 series Digital Electromagnetic Water Flow Meter with RS485 Signal should be installaed behind pump and the value should installa at downstream. 

2. Installa the flow sensor

  • Must to ensure the pipeline is fulled and without bubbles to keep the high accuracy; 
  • The flow direction shoudl keep with sign on the body of flowmeter; 
  • Ensure the double electrodes keep Horizontal; 
  • If the medium is mixed by liquid and solid, Pls installa it at vertical to extend the working life of lining; 
  • If the environment with shocked pls installa the bracket at both front and behind; 
  • If the medium is pollution liquid, should installa the flow meter at bypass pipe and don't interrupted when you on service; 

3. Requirement of Straight pipe

  • The straight of pipe at inlet must more than 10×DN, Suggest 15DN; At outlet, the straight pipe at least 5×DN; 
  • If at the upstearm of flowmeter, there are values, elbow, the straight must need 15×DN; 
  • Pls installa the shut-off value at both front and behind of flow meter; 

4. Installation advance

  • The installation location for you reference




Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter
[Company Information] 
  • Our Company is Top 10 Manufacture on Alibaba; 
  • We have about 30 years of experience in Manufacture; 
  • Our products have been exported to more 100 coutries and area; 
  • ISO, SGS, CE and more ceterficates for you reference; 
  • Patent technology and more than 3 years working life




Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter


 

Send your message to this supplier

*From:
*To:
avatar Ms. Agnes Peng
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter pictures & photos
Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter
US $342-360 / Piece
Min. Order: 1 Piece
Diamond Member Since 2009

Suppliers with verified business licenses

Trading Company
Number of Employees
16
Management System Certification
ISO9001:2015