• Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter
  • Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter
  • Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter
  • Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter
  • Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter
  • Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter

Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter

After-sales Service: Online After-Sales Service
Warranty: 1year
Accuracy: ±0.2-0.5%
Main Application: Water, Wastewater, Corrosive Liquid/Gas
Size: DN50-100
Sensor: Tube/Flange
Samples:
US$ 360/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2009

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Show
  • Company Profile
Overview

Basic Info.

Model NO.
CX-EMFM
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO, SGS
Medium
Liquid
Flow Range
0.16-25000 M³/H
Connection
Flange
Output
Pulse/4-20mA/RS485
Lining Material
PTFE/Rubber
Electrode Material
SS316
Body Material
Carbon Steel/SS304
Power Supply
220V/24V/Lithium Battery
Pressure
10bar
Type and IP Code
Integrated Type IP65, Remote Type IP68
Transport Package
Carton
Trademark
GN
Origin
China
HS Code
9026100000
Production Capacity
5000PCS/Month

Product Description





Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter

 Electromagnetic Flowmeter (CX-HEMFM)

This technology of magnetic electromagnetic flowmeter has a number of advantages when it comes to liquid flow measurement. The sensors are generally inserted in line into the pipes' diameter, and are therefore designed such that they do not disturb or restrict the flow of the medium under measurement. As the sensors are not directly immersed in the liquid-there are no moving parts-there are no wear and tear concerns. 

The method of magnetic electromagnetic flowmeter measures the volume flow, which means the measurement is insensitive to changes in effects such as fluid density, temperature, pressure, and viscosity. Once the electromagnetic water flow sensor measurement transmitter meters is calibrated with water, it can be used to measure the other types of conductive fluid-with no additional correction. This is a significant advantage that other types of flow meters don't have. 

What's the technical parameters of magnetic electromagnetic flowmeter? 

Production Name Magnetic electromagnetic flowmeter
Medium Water; Wastewater; Mud and varioue kinds of conductivity liquid
Diameter DN10~DN2000mm
Accuracy +/-0.5%
Temperature <80ºC(rubber); <180ºC(PTFE)
Pressure 4.0MPa(DN10~80); 1.6MPa(DN100~150); 1.0MPa(DN200~1000); 0.6MPa(DN1200~2000)
Flow speed 0.3~10m/s
Requirement of pipeline Upstream ≥5DN; Downstream≤3DN
Electrode Stainless steel 316L(standard); Titanium; Tantalum; Hastelloy
Lining PTFE; Rubber
Connection Flange; Thrad; Clamp on
Body material Cast steel; Stainless steel
Power supply 220V; 24V; Battery
Output Pulse; 4~20mA; HART; RS485; MODBUS; GPRS
Communication HART; RS485; MODBUS
Explosion proof Customized
Protection IP65 or IP68
Environment Environment: -20~60ºC
Power <20W

 

Item The Electrode table
Material The Medium
SS316L For: Living water; Wastewater; Corrovise water and Mud, etc; 
Hastelloy B For: Non-oxidizing acids at concentrations less than 10%; NAOH Concentrations less than 50%
Hastelloy C For: Mixed Acid and Oxidizing salts
Titanium For: Salt and weak acid; Not application: Hydrochloric acid, nitric acid and other reducing acids
Tantalum For: Hydrochloric acid(<40%); Sulfuric acid and Other oxidizing acids
Plantinum For: Almost all acid-base salt solution But not application for aqua regia, except ammonium salt
Tungsten carbide For: Pulp; Sewage; Slurry

 

Product Show

Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow MeterDigital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow MeterDigital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow MeterDigital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow MeterDigital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow MeterDigital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow MeterDigital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow MeterDigital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow MeterDigital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow MeterDigital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter

Company Profile

Digital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow MeterDigital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow MeterDigital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow MeterDigital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow MeterDigital Electromagnetic Flowmeter Turbine Vortex Oil Flow Meter Liquid Water Magnetic Flow Meter


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2009

Suppliers with verified business licenses

Trading Company
Number of Employees
16
Management System Certification
ISO9001:2015