• Split Type Ultrasonic Flow Meter (CX-TDS)
  • Split Type Ultrasonic Flow Meter (CX-TDS)
  • Split Type Ultrasonic Flow Meter (CX-TDS)
  • Split Type Ultrasonic Flow Meter (CX-TDS)
  • Split Type Ultrasonic Flow Meter (CX-TDS)
  • Split Type Ultrasonic Flow Meter (CX-TDS)

Split Type Ultrasonic Flow Meter (CX-TDS)

Accuracy: ±0.6-1%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Size: </=DN6000
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Split Type Ultrasonic Flow Meter (CX-TDS) pictures & photos
Split Type Ultrasonic Flow Meter (CX-TDS)
US $154 / Piece
Min. Order: 1 Piece
Diamond Member Since 2009

Suppliers with verified business licenses

Secured Trading Service
Trading Company

Basic Info.

Model NO.
CX-TDS
Sensor
Flange, Thread, Insertion
Application
Industrial Production
Type
Ultrasonic Flow Meter
Measuring Media
Liquid
Measuring Principle
Ultrasonic
Measurement Object
Closed Pipe or Open Pipe
Certification
CE, ISO
Max Temp
160c
Max Size
6000mm
Output and Communitaion
Pulse, 4-20mA, RS485, RS232
Certificate
ISO, CE, SGS
Transport Package
Carton/Polywood Case /Wood Case
Specification
CE/SGS/ISO
Trademark
GN
Origin
Shanghai China
HS Code
9026100000
Production Capacity
1000PCS/Month

Product Description

1.Brief introduction of CX-HUFM-TDS-100H Handable ultrasonic flowmeter
1.Widely used to measure liquid flow in various industries
2.Smart body, high accuracy, good repeatability,long-running cell,easy operation,built-in printer etc.
3.Very popular in industry like petrochemical, water, power, energy monitoring etc. It's
4.Exported to Japan, Korea, Australia, America etc.
 
Main features
1.Accuracy:±1%
2.Repeatability:±0.2%
3.Easy to install outside the pipe
4.Four line display: Instantaneous flow rate,Accumulate flow,status
5.Standard interface RS232 for data output and on-line operation
6.Self-diagnose to show the current status
7.Built-in Nickel-hydrogen cell supports 10 hours of operation
High Accuracy Handheld Ultrasonic Flow Meter (CX-TDS)
A.[Features of ultrasonic flowmeter ]

All kinds of liquid
The insertion type ultrasonic flowmeter could measure all kinds of liquid beacuse it don't contact the medium;

Threee kinds of type for you reference
There are three types insertion type ultrasonic flowmeter ,based on your working condition;
Various communication and output 
4~20mA Output ,RS232 and RS485 optional and satisfy your working conditions;
Easy installation and operation
various installation ways and easy to operaton
B.[Parameters]
 Production Name  The insertion type ultrasonic flowmeter
 Parameter  Handheld  Portable  Wall-mounted
 Accuracy 1.0% Flow speed >0.2m/s
 Display  4×8 English display  2×10 backlight display  2×10 backlight display
 Medium  All kinds of liquid
 Function  Data logger  Printer  store data while power off
 Parts  tape,coupling agent,cable  box and coupling agent  Fixed parts
 Linearity  0.5%
 Repeatability 0.2%
 Sensor  15~6000mm standard high temperature sensor
 Output  ----  4~20mA  4~20mA
 Diameter  Min:15mm   Max:6000mm 
 Communication RS232  RS485 MODBUS  RS485
 Power supply  3 Ni-H battery  85~264 VAC   85~264 VAC
 Installaton  External stickers ;External clip-type;Plug-in

 Parameter of Flow Sensor
 Type  Fromat  Model  Diameter  Temperature   Size
 Standard 
 Sandwish
 Normal Small  S-2 DN15~100  -30~90ºC  45*25*32
 Normal Medium  M-1  DN50~700 -30~90ºC  64*39*44
 Normal large  L-1  DN300~6000 -30~90ºC  97*54*53
High temperature
Sandwish
 High-Tem small  S-2-HT  DN15~100 -30~160ºC  45*25*32
 High-Tem medium  M-1-HT  DN50~700 -30~160ºC  64*39*44
 High-Tem large  L-1-HT  DN300~6000 -30~160ºC  97*54*53
 Plug-in  Standard  C-1  DN80~6000 -30~160ºC  190*80*55
 Lengthen  C-2  DN80~6000 -30~160ºC  335*80*55



D.[Company info]
Our Company is Top 10 Manufacture on Alibaba;
We have about 30 years of experience in Manufacture;
Our products have been exported to more 100 coutries and area;
ISO,SGS,CE and more ceterficates for you reference;
Patent technology and more than 3 years working life
             
               
       
   
               
   
     
     
   
               
               
   
   
   
   
   

2.Main features of CX-UFM-TDS-100M Ultrasonic Modular Flowmeter
1.It can work alone without a LCD and keypad module
2.no pressure drop, no moving parts, no leaks and no contamination
3.Integrate the modules into a multi-channel flow meter then can measures several dozen of different pipes
4.Higher accuracy by measures the same pipe with all the channels
5.Easy to install it and don't need special skills or tools
 
Technical parameters
Display: 2x10 LCD indicator to display flow rate, flow speed, total flow
Operation To set with 4 touch keys
Accuracy Better than 1% accuracy  and  0.2% of repeatability
Application Positive/negative/net flow or heat totaliser
Protocol MODBUS/MBUS protocol
Input 4~20mA/PT100 platinum resistance input
Output OCT(Pulse width 6~1000ms, default: 200ms) RS-485/4~20mA output/relay
Power 24VDC for module,85~264VAC/24VDC for display terminal
Protection IP57
Software can be upgrated with code-documents sent by email
Memory 512 days/120month/10years forward-flow / return-flow / Net-flow
Note:The memory will be kept in case of power lost
 
Sensor S1 type M1 type L1 type S1H M1H
Pipe size(DN) 15-100 50-700 300-6000 15-100 50-700
Material ABS Special material for H -temp
Frequency 1MHz
Installation V(N/ W) V/ Z Z V/(N W) V/ Z
calibration Calibrated together with flowmeter
magnetism Magnetic No magnetic
Temperature 32ºF~158ºF(0-70ºC) 32ºF~320ºF(0-160ºC)
Protection class IP65
Dimension(mm) 45*30*30 60*45*45 80*70*55 90*85*24 90*82*29
Weight(g) 75 250 650 94 150
Liquid types Water. Sea water waste water. Chemical liquids. oil, crude oil. alcohol. beer. etc
Suspension concentration ≤20000ppm.may contain very small amount of air bubbles
Pipe material All metals' most plastics, fiber glass etc
Transducer cable Standard length 5 meter×2.can be extended to 10 meter×2 or 15meter×2


3.Main features of CX-UFM-TDS-100P portable type ultrasonic flowmeter
1.Easy to install outside the pipe
2.High accuracy ±1%, good repeatability:±0.2%
3.Long-running cell,easy operation,built-in printer etc
4.two lines display: Instantaneous flow rate,Accumulate flow,status
5.Built-in printer,to print in time and regularly
6.Standard interface RS485 for data output and on-line operation
7.Self-diagnose to show the current status
8.Built-in Nickel-hydrogen cell supports 20 hours of operation
 
Technical parameters
Sensor S1 M1 L1 S1H M1H
Pipe size(DN) 15-100 50-700 300-6000 15-100 50-700
Material ABS Special material for H -temp
Frequency 1MHz
Installation V(N/ W) V/ Z Z V/(N W) V/ Z
calibration Calibrated together with flowmeter
magnetism Magnetic No magnetic
Temperature 32ºF~158ºF(0-70ºC) 32ºF~320ºF(0-160ºC)
Protection class IP65
Dimension(mm) 45*30*30 60*45*45 80*70*55 90*85*24 90*82*29
Weight(g) 75 250 650 94 150
Liquid types Water. Sea water waste water. Chemical liquids. oil, crude oil. alcohol. beer. etc
Suspension concentration ≤10000 ppm with little air bubble
Pipe Carbon steel stainless steel cast iron Brass PVC Aluminum etc.
Pipe liner Rubber Slurry PP PS bakelite,PTFE
Signal cable Standard:5M* 2 optional:10M* 2 or 15M *2


4.Brief introduction of CX-UWM-TDS-100W  Ultrasonic water meter
1.Designed according to Europe alliance EN1434 standard and ultrasonic time-difference principle
2.Ultrasonic time-difference principle Measuring water or other liquid
3.High accuracy, better reliable, no moving part, no need to set data. Install in any angle
4.It can instead of other water meter
 
Main features
1. Accuracy: ±1%,± 2%,Repeatability: ±0.5%
2.Measurement cycle: Default for 3S, 1~31S should be optional by the user
3.Battery can work 6-10years, or two line power
4.Lowest measuring velocity of liquid 0.01m/s
5.No pressure lost and moving parts, no nursing for 10 years
6.Pipe length designing according to the normal water meter
7.IP68, can working under water lower than 2 meters
8.Foundry in mould, no leakage
9.Ceramic sensor apply to -40ºC~160ºC
10.Over look type, normal type, separate type
 
Technical parameters
Pipe ID (mm) Lowest Flowrate
Detectable
Min.Flowrate
qmin
Boundary Flowrate
qt
Max.Flowrate
qmax
Cumulative Flowrate
(m3)
(m3/h) Max Min
15 0.0019 0.0238 0.072 1.5 99999.999 0.001
20 0.0019 0.0238 0.072 2.5
25 0.0045 0.056 0.169 3.0
32 0.0073 0.092 0.275 12
40 0.0114 0.144 0.429 20
50 0.0353 0.35 2.1 150 9999999.9 0.1
65 0.06 0.60 3.58 180
80 Single-path 0.09 0.9 5.43 230
Double-path 0.063 0.9 5.43 230
100 Single-path 0.141 1.41 8.48 300
Double-path 0.099 1.41 8.48 300
125 Single-path 0.221 2.21 13.25 360
Double-path 0.155 2.21 13.25 360
150 Single-path 0.318 3.18 19.08 460
Double-path 0.223 3.18 19.08 460
200 Single-path 0.565 5.6 33.93 660
Double-path 0.396 5.6 33.93 660
4-path 0.226 5.6 33.93 660
250 Single-path 0.883 8.83 53.0 740
Double-path 0.618 8.83 53.0 740
4-path 0.353 8.83 53.0 740
 Split Type Ultrasonic Flow Meter (CX-TDS)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Split Type Ultrasonic Flow Meter (CX-TDS) pictures & photos
Split Type Ultrasonic Flow Meter (CX-TDS)
US $154 / Piece
Min. Order: 1 Piece
Diamond Member Since 2009

Suppliers with verified business licenses

Secured Trading Service
Trading Company
Number of Employees
16
Management System Certification
ISO9001:2015