Basic Info.

Model NO.
cx
Standard
Standard
Application
Garage
Response Time
2s
Transport Package
Carton
Specification
CE SGS
Trademark
GN
Origin
Shanghai Cixi
HS Code
9026100000
Production Capacity
1000PCS/Month

Product Description

CXFR11 series Electronic flow sensor, also known as differential thermal flow sensor and Thermal flow sensor. The set range can be 1-20m/s. Have relay output (230VAC. 4A) and 4-20mA output. Suitable for different kinds fluid. Concise and direct indicator, and with high reliable.

Feature
1, No movable parts.
2, Maintenance free.
3, Easy installation.
4, Suitable for variable diameter demand.
5, Switching value can be adjusted continuously.
6, Extremely low pressure loss.
7, Compact structure.
8, LED indicator display flow trend and switch state.

Technical data
1. Set range: 1^150cm/s( water), 3^300cm/s(oil), 20^2000cm/s(air)
2. Output: PNP, NPN, Relay, NO+NC (SPDT)
3. Power supply: 24V± 20%DC or 230V± 15%AC
4. Switching Current: Max. 400mA(PNP or NPN type ), Max. 4A( Relay type )
5. Unload current: Max. 80mA
6. Flow indicator: LED (6)
7. Set type: Potentiometer set
8. Proof Pressure range: 100bar
9. Temperature gradient: 4 C/s
10. Response time: 1--13s, standard is 2s
11. Initialization time: 8s
12. Electrical protection: Reversed-phase, short circuit, overload protection
13. Protection class: IP67
14. Medium temperature: -20--80C
15. Environment temperature: -20--80C
16. Storage temperature: -20--100C
17. Connection: M12 connector /2m cable (option)
18. Material: Probe is stainless steel. Housing is PBT.
19. Weight: 0.4kg
Most Accurate Control By Electronic Thermal Mass Water Flow Switch
                                    -----------We are gold supplier in 9 consecutive years
     CX-FS series Electronic thermal mass  flow switch , also known as differential thermal flow sensor and Thermal flow sensor . The set range can be 1-20m/s . Have relay output (230VAC.4A). Suitable for different kinds fluid .Concise and direct indicator ,and with high reliable .
     The Principle of electronic thermal mass flow switch based on the principle of thermal theory, there are two resistances in the closed probe . One resistance was heated and regarded as detected resistance , the other one was heated and regarded as standard resistance . When the medium is flowing ,the heat on the heated resistance will be taken away and the resistances' value will be changed . The differential resistances value is the basis of determining the flow velocity .




Application:
gaseous /liquid
The flow switch for ground-source heat-pump is mainly applicable to industrial automation/mechanical equipment/air compressing industry/ refrigeration and air-conditioner. The magnet not contact with flowing water, so can normally work in sewage discharging system.

CX-FS-FB Paddle Flow Switch
Diameter DN25…DN150
Set range 20…1800L/min(water)
Repeatability ±2.5%FS
Connection terminal type
Output Mechanical switch  NO+NC(250VAC,3A)
Pressure proof 16 bar
Average pressure loss: 0.08bar( at max.flow rate)
Ambient temperature -25…80C
Medium temperature 0…90C
Interface screw G1"pipe screw
Protective class IP33
Weight 0.55kg
Material Main body stainless steel
Process connection: brass
Connection rod brass
Baffle stainless steel
Seal  NBR
Housing ABS

CX-FS-FB12 Baffle Flow Switch
Repeatability ±2.5%FS
Connection terminal type
Output Mechanical switch  NO+NC(250VAC,3A)
Pressure proof 16 bar
Average pressure loss: 0.08bar( at max.flow rate)
Ambient temperature -25…80ºC
Medium temperature 0…90ºC
Interface screw G1"pipe screw
Protective class IP33
Weight 0.85kg
Material Main body stainless steel
Process connection: brass
Connection rod brass
Baffle brass
Seal NBR
Housing ABS

CX-FS-FPD20 Pointer display type piston flow switch
Medium liquid or gas
Repeatability ≤±3%full scale
Pressure 200bar(stainless steel type)100bar(brass type)
Output normally open output
Contact capacity 240VAC / 110VDC 1.5A
Ambient temperature -20…70ºC
Medium temperature 0…70ºC
Protection IP65
Outlet M12*1
Material Electronic body PC
Switch body stainless steel / brass nickel plating
Spring stainless steel

CX-FS-FR11 Electronic Flow Sensor
Set range 1…150cm/s( water),3…300cm/s(oil),20…2000cm/s(air)
Output PNP, NPN, Relay ,4-20mA, NO+NC (SPDT)
Power supply 24V±20%DC or 230V±15%AC
Switching Current Max.400mA(PNP or NPN type ), Max.4A( Relay type )
Unload current Max.80mA
Flow indicator LED (6)
Set type potentiometer set
Proof Pressure range 100bar
Temperature gradient 4ºC/s
Response time 1--13s,standard is 2s
Initialization time 8s
Electrical protection reversed-phase ,short circuit ,overload protection
Protection class IP67
Medium temperature 20--80ºC
Environment temperature -20--80ºC
Storage temperature -20--100ºC
Connection M12 connector /2m cable (option)
Material Probe is stainless steel . Housing is PBT
Weight 0.4kg
 
CX-FR-FR12 Electronic flow switch
Set range 1…150cm/s( water),3…300cm/s(oil),20…2000cm/s(air)
Output PNP, NPN, Relay ,4-20mA, NO+NC (SPDT)
Power supply 24V±20%DC
Switching Current Max.400mA(PNP or NPN type ), Max.4A( Relay type )
Unload current Max.80mA
Flow indicator LED (6)
Set type potentiometer set
Proof Pressure range 100bar
Temperature gradient 4ºC/s
Response time 1--13s,standard is 2s
Initialization time 8s
Electrical protection reversed-phase ,short circuit ,overload protection
Protection class IP67
Medium temperature 20--80ºC
Environment temperature -20--80ºC
Storage temperature -20--100ºC
Connection M12 connector /2m cable (option)
Material Probe is stainless steel . Housing is PBT
 
Model Connection Notes Accuracy
HFS-25 1″-11½NPT Screw Red Case 5%
HFS-20 ¾″-14NPT Screw
HFS-15 ½″-14NPT Screw
JYF-25 1″-11½NPT Screw White Case 2-3%
JYF-20 ¾″-14NPT Screw
JYF-15 ½″-14NPT Screw
Rated Voltage?Rated Amps A.C.125~250V Power(Cosmp.)  
Non-inductive Current 12A 1  
Full Load 12A 0.75  
Locked Roter 72A 0.45  
Required Flow for actuating switch (m3/h)  
Pipe size (in) 1 1-¼ 1-½ 2 2-½ 3 4 5 6 8  
Min.
Flow
Flow lower,1-2 closed 1 1.3 1.7 3.1 4.1 6.2 8.4 12.9 16.8 46.6  
Flow lower,1-3 closed 0.6 0.8 1.1 2.2 2.8 4.3 6.1 9.3 12.3 38.6  
Max.
Flow
Flow lower,1-2 closed 2 3 4.4 6.6 7.8 12 18.4 26.8 32.7 94.2  
Flow lower,1-3 closed 1.9 2.8 4.1 6.1 7.3 11.4 17.3 25.2 30.7 90.8  
 
   
   
   
Fan Air Flow Switch with

Send your message to this supplier

*From:
*To:
avatar Ms. Agnes Peng
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2009

Suppliers with verified business licenses

Trading Company
Number of Employees
16
Management System Certification
ISO9001:2015