Compact Handheld Ultrasonic Flow Meter for Field Flow Testing and Monitoring

Product Details
Customization: Available
After-sales Service: Online After-Sales Service
Warranty: One Year
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (24)
  • Compact Handheld Ultrasonic Flow Meter for Field Flow Testing and Monitoring
  • Compact Handheld Ultrasonic Flow Meter for Field Flow Testing and Monitoring
  • Compact Handheld Ultrasonic Flow Meter for Field Flow Testing and Monitoring
  • Compact Handheld Ultrasonic Flow Meter for Field Flow Testing and Monitoring
  • Compact Handheld Ultrasonic Flow Meter for Field Flow Testing and Monitoring
  • Compact Handheld Ultrasonic Flow Meter for Field Flow Testing and Monitoring
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
CX-HUFM-TDS
Accuracy
±0.6-1%
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Size
DN100-500
Sensor
Clamp-on/External
Application
Industrial Production
Type
Ultrasonic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Open Channel
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Product Name
Handheld Ultrasonic Flow Meter
Applicable Caliber
DN15–DN6000
Flow Rate
0.01–25m/S
Protection Level
IP65
Max Temperature
160ºC
Transport Package
Carton
Specification
CE SGS
Trademark
GN
Origin
Shanghai
HS Code
90261000
Production Capacity
1000PCS/Month

Packaging & Delivery

Package Size
45.00cm * 45.00cm * 40.00cm
Package Gross Weight
7.500kg

Product Description

Product Description


Compact Handheld Ultrasonic Flow Meter for Field Flow Testing and Monitoring1.0% High Accuracy Widely Measuring Range Digital Portable Ro Water Flow Meter

A.[Features of ultrasonic flowmeter ]

 

All kinds of liquid

The insertion type ultrasonic flowmeter could measure all kinds of liquid beacuse it don't contact the medium;

 

Threee kinds of type for you reference

There are three types insertion type ultrasonic flowmeter ,based on your working condition;

Various communication and output 

4~20mA Output ,RS232 and RS485 optional and satisfy your working conditions;

Easy installation and operation

various installation ways and easy to operaton

B.[Parameters]

 Production Name  The insertion type ultrasonic flowmeter
 Parameter  Handheld  Portable  Wall-mounted
 Accuracy 1.0% Flow speed >0.2m/s
 Display  4×8 English display  2×10 backlight display  2×10 backlight display
 Medium  All kinds of liquid
 Function  Data logger  Printer

 store data while power off

 Parts  tape,coupling agent,cable  box and coupling agent  Fixed parts
 Linearity  0.5%
 Repeatability 0.2%
 Sensor  15~6000mm standard high temperature sensor
 Output  ----  4~20mA  4~20mA
 Diameter  Min:15mm   Max:6000mm 
 Communication RS232  RS485 MODBUS  RS485
 Power supply  3 Ni-H battery  85~264 VAC   85~264 VAC
 Installaton  External stickers ;External clip-type;Plug-in

Compact Handheld Ultrasonic Flow Meter for Field Flow Testing and Monitoring
Compact Handheld Ultrasonic Flow Meter for Field Flow Testing and Monitoring

 Parameter of Flow Sensor
 Type  Fromat  Model  Diameter  Temperature   Size

 Standard 

 Sandwish

 Normal Small  S-2 DN15~100  -30~90ºC  45*25*32
 Normal Medium  M-1  DN50~700 -30~90ºC  64*39*44
 Normal large  L-1  DN300~6000 -30~90ºC  97*54*53

High temperature

Sandwish

 High-Tem small  S-2-HT  DN15~100 -30~160ºC  45*25*32
 High-Tem medium  M-1-HT  DN50~700 -30~160ºC  64*39*44
 High-Tem large  L-1-HT  DN300~6000 -30~160ºC  97*54*53
 Plug-in  Standard  C-1  DN80~6000 -30~160ºC  190*80*55
 Lengthen  C-2  DN80~6000 -30~160ºC  335*80*55

Compact Handheld Ultrasonic Flow Meter for Field Flow Testing and MonitoringCompact Handheld Ultrasonic Flow Meter for Field Flow Testing and Monitoringhttps://gnflowmeter.en.made-in-china.com/contact-info.html

Company Profile

Compact Handheld Ultrasonic Flow Meter for Field Flow Testing and MonitoringCompact Handheld Ultrasonic Flow Meter for Field Flow Testing and MonitoringCompact Handheld Ultrasonic Flow Meter for Field Flow Testing and MonitoringCompact Handheld Ultrasonic Flow Meter for Field Flow Testing and MonitoringCompact Handheld Ultrasonic Flow Meter for Field Flow Testing and MonitoringCompact Handheld Ultrasonic Flow Meter for Field Flow Testing and Monitoring

FAQ

Handheld Ultrasonic Flow Meter FAQ

(Based on technical manuals and field maintenance cases)

1. Signal Reception Failure

Q: No signal/weak signal?
Causes: Incorrect pipe parameters, insufficient couplant, misaligned probes, or non-full pipe.
Solutions:
Verify pipe OD/wall thickness (input measured values)
Reapply couplant generously, eliminate air bubbles before securing probes
Ensure fluid fills the pipe; install probes at screen-indicated distances (Red upstream, Blue downstream)

Q: Weak signal in aged pipes?
Causes: Scaling or internal deformations blocking ultrasound.
Solutions:
Use Z-mount method (angle probes to avoid scaled areas)
Relocate probes to find optimal signal points or lightly tap pipe (use cautiously)

2. Display Abnormalities
Q: Blank screen/no backlight?
Causes: Power disconnection or protective shutdown.
Solutions: Check 220V supply, restart device.

Q: Zero flow reading (actual flow present)?
Causes: Accidental activation of static zero function (M43 menu).
Solutions: Enter menu > clear static zero point > select "YES" to reset.

Q: Significant flow value deviation?
Causes: Insufficient straight pipe (near valves/pumps), sensor misalignment, or parameter errors.
Solutions:
Relocate to >10 pipe diameters upstream of disturbances
Recalibrate sensor spacing; confirm pipe material sound speed settings

3. Output & System Errors
Q: No current loop output?

Causes: Incorrect hardware jumper setting (near terminal 22).
Solutions: Set jumper to 1-2 position (direct output mode).

Q: Data storage/time errors?
Causes: RAM or RTC module malfunction.
Solutions: Restart device; contact manufacturer if persistent.

4. Environmental Limitations
Q: Failure in high-purity/hot fluids?
Causes: Decoupling >160°C (probes) or lack of reflectors in pure liquids (Doppler mode).
Solutions:
Use high-temp probes with thermal insulation
Switch to transit-time method or inject particles for Doppler

Q: Erratic readings?
Causes: Pipe vibration or fluid bubbles/impurities.
Solutions:
Reinforce pipe supports; avoid vibration sources
Install vent valves at high points; mount vertically (bottom-up flow)

5. Maintenance Issues
Q: Rapid battery drain?
Causes: Battery aging, interrupted charging, or firmware incompatibility.
Solutions: Replace OEM battery; perform full discharge/charge cycle; update firmware.
Critical Operation Notes

Probe Installation:
Polish pipe to bare metal before mounting - rust/paint attenuates signals.
Periodically calibrate current loop (M49 verification) and sensor spacing.

 